Welcome to our websites!
  • UCF211

    UCF211

    Bearing Unit No. Shaft Dia. Dimensions (in.)or(mm) Bolt Used Bearing No. Housing No. Weight(kg) d (in.) (mm) a e i g l s z t B n (in.) (mm) UCF211 55 162 130 25 20 43 19 58.4 63 55.6 22.2 M16 UC211 F211 3.09/3.78 UCF211-32 2 6-3/8 5-1/8 63/64 25/32 1-11/16 3/4 2-5/16 2-31/64 2.1890 0.874 5/8 UC211-32 F211 3.24 UCF211-33 2-1/16 6-3/8 5-1/8 63/64 25/32 1-11/16 3/4 2-5/16 2-31/64 2.1890 0.874 5/8 UC211-33 F211 3.24 UCF211-34 2-1/8 6-3/8 5-1/8 63/64 25/32 1-11/16 3/4 ...
  • UCF212

    UCF212

    Bearing Unit No. Shaft Dia. Dimensions (in.)or(mm) Bolt Used Bearing No. Housing No. Weight(kg) d (in.) (mm) a e i g l s z t B n (in.) (mm) UCF212 60 175 143 29 20 48 19 68.7 73.5 65.1 25.4 M16 UC212 F212 4.31/4.62 UCF212-36 2-1/4 6-57/64 5-5/8 1-9/64 25/32 1-57/64 3/4 2-45/64 2-57/64 2.5630 1.000 5/8 UC212-36 F212 4.31 UCF212-37 2-5/16 6-57/64 5-5/8 1-9/64 25/32 1-57/64 3/4 2-45/64 2-57/64 2.5630 1.000 5/8 UC212-37 F212 4.31 UCF212-38 2-3/8 6-57/64 5-5/8 1-9/64 2...
  • UCF213

    UCF213

    Bearing Unit No. Shaft Dia. Dimensions (in.)or(mm) Bolt Used Bearing No. Housing No. Weight(kg) d (in.) (mm) a e i g l s z t B n (in.) (mm) UCF213   65 187 149 30 22 50 19 69.7 74.5 65.1 25.4   M16 UC213 F213 5.21/5.4 UCF213-40 2-1/2   7-23/64 5-55/64 1-3/16 55/64 1-31/32 3/4 2-3/4 2-15/16 2.5630 1.000 5/8   UC213-40 F213 5.27/5.46 UCF213-41 2-9/16   7-23/64 5-55/64 1-3/16 55/64 1-31/32 3/4 2-3/4 2-15/16 2.5630 1.000 5/8   UC213-41 F213 5.27/5.46 Application...
  • Pillow Block BearingUCF200

    Pillow Block BearingUCF200

    Bearing Unit No. Shaft Dia. Dimensions (in.)or(mm) Bolt Used Bearing No. Housing No. Weight(kg) d (in.) (mm) a e i g l s z t B n (in.) (mm) UCF201   12 86 64 15 12 25.5 12 33.3 37.5 31 12.7   M10 UC201 F201 0.59 UCF201-8 1/2   3-3/8 2-33/64 19/32 15/32 1 15/32 1-5/16 1-31/64 1.2205 0.500 3/8   UC201-8 F201 0.58 UCF202   15 86 64 15 12 25.5 12 33.3 37.5 31 12.7   M10 UC202 F202 0.58 UCF202-9 9/16   3-3/8 2-33/64 19/32 15/32 1 15/32 1-5/16 1-31/64 1.2205 0.500 3/8   UC...
  • LSGR-207

    LSGR-207

    S seal on the base side and 3-lip seal with Metal flinger ring on the front side which is exposed to contaminants.

    The 3-lip seal on the front side protects the bearing from contaminant penetration. The metal flinger ring protects the seal from mechanical damage.
  • LSF207

    LSF207

    Dual sealing, protection cover placed on the inner ring protects against rough impurity particles and makes the labyrinth with the sheet part of the seal; then the sealing S type, with the labyrinth between the sheet part and the rubber lip that conducts the contact sealing. The friction and speeds are the same as with S but has much better protection against rough impurity particles. It is very good sealing system: the sheet part protects the seal from the soil, dust and rough particles. At the same time makes the labyrinth with the rubber part. The rubber part provides the contact sealing that prevents the penetration of the finer impurities, water, moisture, steam etc. Suitable for heavier conditions due to better protection against foreign matters. It is used with the Y bearings (standard).
  • UCF210

    UCF210

    Bearing Unit No. Shaft Dia. Dimensions (in.)or(mm) Bolt Used Bearing No. Housing No. Weight(kg) d (in.) (mm) a e i g l s z t B n (in.) (mm) UCF210 50 143 111 22 18 40 16 54.6 59.5 51.6 19 M14 UC210 F210 2.32 UCF210-29 1-13/16 5-5/8 4-3/8 55/64 23/32 1-9/16 5/8 2-5/32 2-11/32 2.0315 0.748 1/2 UC210-29 F210 2.44 UCF210-30 1-7/8 5-5/8 4-3/8 55/64 23/32 1-9/16 5/8 2-5/32 2-11/32 2.0315 0.748 1/2 UC210-30 F210 2.39 UCF210-31 1-15/16 5-5/8 4-3/8 55/64 23/32 1-9/16 5/8 2...
  • UCF204

    UCF204

    Bearing Unit No. Shaft Dia. Dimensions (in.)or(mm) Bolt Used Bearing No. Housing No. Weight(kg) d (in.) (mm) a e i g l s z t B n (in.) (mm) UCF204 20 86 64 15 12 25.5 12 33.3 37.5 31 12.7 M10 UC204 F204 0.55 UCF204-12 3/4 3-3/8 2-33/64 19/32 15/32 1 15/32 1-5/16 1-31/64 1.2205 0.500 3/8 UC204-12 F204 0.56 Application scenarios The role of UCF bearings ‌ Insulating glass production line ‌UCF bearing is used in insulating glass production line equipment to ens...
  • UCF205

    UCF205

    Bearing Unit No. Shaft Dia. Dimensions (in.)or(mm) Bolt Used Bearing No. Housing No. Weight(kg) d (in.) (mm) a e i g l s z t B n (in.) (mm) UCF205 25 95 70 16 14 27 12 35.8 40 34.1 14.3 M10 UC205 F205 0.77/0.89 UCF205-13 13/16 3-3/4 2-3/4 5/8 35/64 1-1/16 15/32 1-13/32 1-9/16 1.3425 0.563 3/8 UC205-13 F205 0.77 UCF205-14 7/8 3-3/4 2-3/4 5/8 35/64 1-1/16 15/32 1-13/32 1-9/16 1.3425 0.563 3/8 UC205-14 F205 0.77 UCF205-15 15/16 3-3/4 2-3/4 5/8 35/64 1-1/16 15/32 1-13...
  • UCF206

    UCF206

    Bearing Unit No. Shaft Dia. Dimensions (in.)or(mm) Bolt Used Bearing No. Housing No. Weight(kg) d (in.) (mm) a e i g l s z t B n (in.) (mm) UCF206 30 108 83 18 14 31 12 40.2 44.5 38.1 15.9 M10 UC206 F206 1.12 UCF206-17 1-1/16 4-1/4 3-17/64 45/64 35/64 1-7/32 15/32 1-19/32 1-3/4 1.5000 0.626 3/8 UC206-17 F206 1.13 UCF206-18 1-1/8 4-1/4 3-17/64 45/64 35/64 1-7/32 15/32 1-19/32 1-3/4 1.5000 0.626 3/8 UC206-18 F206 1.13 UCF206-19 1-3/16 4-1/4 3-17/64 45/64 35/64 1-7/3...
  • UCT205

    UCT205

    Model Appearance size(mm) kg Model Model of matched bearing pedestal D B S L L1 L2 H H1 A A1 A2 N N1 N2 UCT205 52 31.4 14.3 97 62 10 89 76 32 12 24 19 16 32 0.9 UC205 T205
  • UCT201